System Biosciences

ExoGlow-NTA Fluorescent Labeling Kit (for Malvern NanoSight)

(No reviews yet) Write a Review
SKU:
EXONTA200A-1
Availability:
Usually Shipped in 5 Working Days
Size:
10 reactions
Shipping Temperature:
Blue Ice
  • ExoGlow-NTA Fluorescent Labeling Kit (for Malvern NanoSight)
  • ExoGlow-NTA Fluorescent Labeling Kit (for Malvern NanoSight)
$577.20

Description

ExoGlow-NTA Fluorescent Labeling Kit (for Malvern NanoSight). Cat# EXONTA200A. Supplier: SBI System Biosciences

Overview

Just see extracellular vesicles with Nanoparticle Tracking Analysis (NTA) Making a great exosome research tool even better, SBI has developed ExoGlow-NTA Labeling Kit (for Malvern NanoSight), a proprietary dye that enables fluorescent NTA analysis of only the extracellular vesicles present in a heterogenous sample. The result is more accurate EV NTA data that excludes protein aggregates, membrane fractions, and other background particles to provide EV-specific particle size and concentration.
  • The only commercially available kit that specifically labels EVs for fluorescent NTA quantitation
  • Delivers high signal-to-noise ratio with a proprietary dye that specifically detects EVs
  • Validated using common EV isolation methods including as ExoQuick, ultracentrifugation, and column-based methods
  • Optimized for a fast protocol that takes only 30 minutes from isolated sample to analysis

How It Works

Gain more accurate insight into your exosome sample

The ExoGlow-NTA Fluorescent Labeling Kit (for Malvern NanoSight) takes advantage of the fluorescence capabilities of nanoparticle tracking analysis instrumentation with a proprietary fluorescent dye, which works by reacting specifically and efficiently to the surface of intact vesicles. Membrane fragments, protein aggregates, and other background particles do not activate the ExoGlow-NTA dye, resulting in exclusion of these species from fluorescent NTA analysis (Figure 1). Thus, with the ExoGlow-NTA Kit, the data delivered by NTA more accurately represents the EV populations in your sample rather than all particles, as is typically reported by conventional (non-fluorescent) NTA.

Figure 1. The ExoGlow-NTA dye only binds to membranes of intact EVs. Unlike conventional NTA, which collects data on all particles in a solution based on light scattering, the fluorescence mode of the NTA instrument selectively detects the labeled EVs and only the data from fluorescently-labeled particles is reported.

The ExoGlow-NTA Fluorescent Labeling Kit comes with three components: 1) Labeling dye 2) Standard and 3) Reaction Buffer. Simply mix the dye with the reaction buffer, add 1-100 µg of EVs (or protein equivalent), incubate for 5 minutes, and you are ready for fluorescent NTA analysis. The provided Internal Standards are size-controlled synthetic liposomes that provide a positive control for NTA calibration as well as EV/exosome labeling efficiency using the ExoGlow-NTA Kit.

Don’t have access to an NTA instrument? SBI also offers fluorescent NTA as a service. Simply send us your samples, and we will isolate, label, and perform fluorescent NTA on your EVs. Email our Services department to request a quote now.

Supporting Data

Better NTA data on exosomes using ExoGlow-NTA

SBI’s ExoGlow-NTA Fluorescent Labeling Kit delivers highly accurate EV quantitation in a quick and easy workflow. The proprietary dye offers highly efficient labeling (Figure 2), very low background (Figure 3), and is compatible with a wide range of EV isolation techniques (Figure 4).

Figure 2. ExoGlow-NTA-labeled liposomes deliver consistent NTA data whether in light scattering or fluorescent mode. The high concordance of NTA and fluorescent NTA data collected from the ExoGlow-NTA Kit internal standards (ExoGlow-NTA-labeled synthetic liposomes) demonstrates the labeling efficiency of the ExoGlow-NTA Dye and accuracy of the fluorescent NTA method for characterizing EVs.

Figure 3. ExoGlow-NTA delivers undetectable background signal. When analyzing the ExoGlow-NTA dye alone in PBS, conventional NTA picks up background particles in the absence of EVs, while fluorescent NTA of the ExoGlow-NTA dye alone shows bias-free undetectable autofluoresence, based on (A) particle counts and (B) imaging.

Figure 4. ExoGlow-NTA demonstrates that conventional NTA overestimates EV concentration in samples irrespective of EV isolation method. Representative data comparing conventional NTA and fluorescent NTA for EVs isolated using (A) ExoQuick (10 µg serum protein), (B) ultracentrifugation and wash (1 µg serum protein), or (C) column-based isolation (1 µg serum protein), shows just how much of the conventional NTA signal is due to non-EV particles.

 

View AllClose