System Biosciences

FluoroCet Exosome Quantitation Kit

(No reviews yet) Write a Review
SKU:
FCET96A-1
Availability:
Usually Shipped in 5 Working Days
Size:
96 reactions
Shipping Temperature:
Blue Ice
  • FluoroCet Exosome Quantitation Kit
  • FluoroCet Exosome Quantitation Kit
€779.00

Description

FluoroCet Exosome Quantitation Kit. Cat# FCET96A. Supplier: SBI System Biosciences

Overview

Get ultrasensitive exosome quantitation when samples are limiting
Enabling highly sensitive quantitation of exosomes in only 60 minutes, the FluoroCet Kit takes our popular EXOCET assay and increases the sensitivity over 30-fold. Fully compatible with all of SBI’s ExoQuick® exosome isolation reagents as well as ultracentrifugation, FluoroCet is great for quantifying exosomes when samples are limiting.
  • Sensitive
    • Requires as little as 500 ng of exosomal protein
    • Perfect for clinical samples or any situation where samples are limiting
  • Fast—assay is complete in only 60 minutes
  • Versatile—compatible with all major exosome isolation methods (e.g. ExoQuick, ultracentrifugation, ultrafiltration, and immunoffinity capture) from human, mouse, and rat samples
  • Quantitative—internal assay standards enable calculation of exosome abundance
Like EXOCET, FluoroCet measures the activity of acetecylcholinesterase (AChE), a known exosome protein, although the more sensitive FluoroCet assay relies on readout of fluorescence emission at 590-600 nm. To enable calculation of exosome abundance in your target sample, each kit includes standards calibrated to known amounts of human exosomes as determined by NanoSight analysis. The FluoroCet Kit contains all of the reagents needed to perform 96 reactions.
Choose the exosome quantitation method that’s best for your studies
 

How It Works

Exosome quantitation with FluoroCet is quick and easy

  1. Calibrate your fluorescence plate reader
  2. Isolate exosomes (ExoQuick, ExoQuick-TC, ExoQuick PLUS, and ExoQuick-TC PLUS are all excellent methods)
  3. Lyse exosomes with the included Exosome Lysis Buffer
  4. Measure AChE activity—add the included buffer and incubate for 20 minutes (or appropriate time as determined during the calibration step) at room temperature in the dark, and then measure fluorescence using excitation at 530–570 nm and emission at 590–600 nm.

Supporting Data

The sensitive FluoroCet exosome quantitation assay

 

Data from FluoroCet remains linear—and quantitative—even at low exosome amounts. Comparison of limit of detection (LOD) of EXOCET versus FluoroCet.

 

View AllClose